Modern GeMech piling machine

Restricted Access in Avonmouth

We’re installing steel cased bottom driven piles inside an existing warehouse in Avonmouth. With restricted headroom of between 6.0m – 5.5m, the mast on our Vermeer HL-2500 is able to reduce down to allow it to work in tight access sites without compromise on performance. A total of 107nr. 220mm steel casings driven to 12.0m with refusal on the Mercia Mudstone.